Certification & Quality Approvals

> Meeting industrial certifications specific to different industries

Certified to perform in even the harshest environments

Winmate promotes standardization of material, facilities, and engineering practices to improve industrial safety standards and regulations, while reducing the total cost of ownership and acquisition cycle time. Our materials, tools, facilities, engineering, and testing practices are designed to ensure reliability and durability.

 

At Winmate we developed and implemented a quality management system based on a process management approach. This allows us to maintain consistency in product service and support, and meet all applicable regulatory requirements, while remaining nimble and flexible enough to evolve with technology and industry need. The quality system complies with the international standard ISO 9001:2008 and the standards which apply to related industries.

 

Below are the standards we adhere to:

  • MIL-STD-810G

    The MIL-STD-810 test series are approved for use by all departments and agencies of the United States Department of Defense (DoD). MIL-STD-810 addresses a broad range of environmental conditions that include: low pressure for altitude testing; exposure to high and low temperatures plus temperature shock (both operating and in storage); rain (including wind blown and freezing rain); humidity, fungus, salt fog for rust testing; sand and dust exposure; explosive atmosphere; leakage; acceleration; shock and transport shock; gunfire vibration; and random vibration. The standard describes environmental management and engineering processes that can be of enormous value to generate confidence in the environmental worthiness and overall durability of a system design.

    MIL-STD-810 Method 501.4 High Temperature
    MIL-STD-810 Method 502.4 Low Temperature
    MIL-STD-810 Method 506.4 Rain / Water Resistance
    MIL-STD-810 Method 507.4 Humidity
    MIL-STD-810 Method 514.5 Vibration
    MIL-STD-810 Method 516.5 Shock
    MIL-STD-810 Method 503.4 Temperature Shock
    MIL-STD-810 Method 500.4 Low Pressure
  • MIL-STD-461F

    MIL-STD-461 is a United States Military Standard that describes how to test equipment for electromagnetic compatibility.

    Specifically, MIL-STD 461F details testing specification to ensure the conducted emissions (CE), conducted susceptibility (CS), radiated emissions (RE), and radiated susceptibility (RS) of a system can meet the requirements for the control of electromagnetic interference.

    MIL-STD-461 Method - CE101/ CE102 Conducted Emissions
    MIL-STD-461 Method - CS101/CS106/CS109/CS114/CS115/CS116 Conducted Susceptibility
    MIL-STD-461 Method - RS101/RS103 Radiated Susceptibility
    MIL-STD-461 Method - RE101/RE102 Radiated Emissions
  • EN50155

    The EN50155 standard is a guidebook that governs the design and testing of electronic equipment used on railway vehicles and related rail applications. To meet the EN50155 requirement, the components must go through a series of strict tests including EMC, cooling, damp heat, salt mist, vibration, and shock tests.

    Type Standard/Regulation
    Cooling EN50155:2001 / 10.2.3
    EN60068-2-1, Test Ad
    Dry Heat (operation) EN50155:2001/ 10.2.4
    EN60068-2-2, test Bd
    Damp heat test, cyclic EN50155:2001 / 10.2.5
    EN60068-2-30, Test Db
    Salt Mist Test EN50155:2001 / 10.2.10
    Vibration Test EN50155:2001/10.2.11
    EN61373 / IEC61373 / Section 8 ,Section 9
    Shock Test EN50155:2001/10.2.11
    EN61373 / IEC61373 / Section 10
    Low temp. storage test EN50155:2001/10.2.14
    EN60068-2-1
    Watertightness Test EN50155:2001/10.2.12
    EN60529
    (IEC 60529)
  • EN61373

    This International Standard specifies the requirements for testing equipment for railway vehicles which are subjected to vibrations and shock. To ensure the operation of the equipments, it has to withstand tests of reasonable duration to simulate the service condition throughout its expected life.

     

    Simulated long-life testing is achieved by amplification, where amplitudes are increased and the time base decreased.

     

    Test carried out on Winmate Equipment using test values for Category 1 Body Mounted, Class B, which is defined as anything mounted inside an equipment case which is turn mounted directly on or under the car body.

  • Class 1 Division 2 Group A-D and ATEX

    Winmate has addressed the Request for Panel PC equipment that can withstand Hazardous Location (Hazloc), where flammable substance may be present with C1D2 (for US and Canada market) and ATEX (for European market) certification on 15-inch Stainless Panel PC. In the US market we follow NEC, which place Hazloc into classes, divisions, and groups. For the rest of the market, IEC Classifies Hazloc by zones.

    NEC
    (National Electric Code)
    According to OSHA, NEC defines hazardous locations as those areas where fire or explosion hazards may exist due to flammable gases or vapors, flammable liquids, combustible dust of ignitable fibers or flyings. NEC classified Hazardous locations in three ways; Type, Condition, and Nature.
    IEC
    (International Electrochemical Commission)
    IEC Defines the flammable gases and vapors and then flammable dust, each of this type are assigned into three different zone and each zone then requires equipment built for category I,II or III
     
    This following figure will help users catch a basic understanding on both classifications
     
    Winmate 15" Stainless Steel Panel PC has passed various tests and certifications for Hazardous area deployment
    America Europe

    Grade
    Class 1 Division 2, Group A,B,C,D, T4

    Grade
    II 3 G Ex nA ic IIA T4

    Certification
    ISA 12.12.01-2012
    CSA C22.2 No.213-M1987
    CSA 22.2 No. 60950-1-07
    FCC

    Certification
    ATEX 94/9/EC
    UL 60950-1
    CE

    Test Report
    IEC 60079-11 , Equipment protection by intrinsic safety "I"
    IEC 60079-15, Equipment protection by type of protection "n"
  • DNV 2.4, IEC60945, IACS-E10

    Winmate marine products are built and tested according to DNV standard certification 2.4, IEC60945, and IACS-E10 and most of the products are certified by Det Norske Veritas (DNV), the Norwegian foundation internationally certifying materials, components and system relevant to safe operation and quality of ships.

    DNV 2.4 DET NORSKE VERITAS (DNV) is an autonomous and independent foundation with the objectives of safeguarding life, property and the environment at sea and on shore. DNV certification related to quality of ships, offshore units and installations of the system and components. DNV Requirements are harmonized with IACS Unified Requirements E10 and IEC publication 60945.
    IACS-E10 International Association of Classification Societies (IACS) is an organization that provides technical support and guidance for promoting the safety of life, property and the environment through the verification of compliance with technical and engineering standards for the design, construction and life-cycle maintenance of ships, offshore units and other marine-related facilities
    IEC 60945 Equipment wished to be use in navigation and radio communication systems is to comply with IEC Publication No. 60945, “Maritime navigation and radio communication equipment and systems – General Requirements- Method of testing and required test results”

    Standard for Certification

    DNV classifies tests in four levels base on the product applied location in ships-A, B, C, and D. For worse harsh environment use, the much strict standard testing is required. (See Table of Location Classes Selection Guide) Standards for Certification including contain principles, acceptance criteria and practical information related to the Society's consideration of objects, personnel, organizations, services and operations. A list of Standards for Certification is found in the latest edition of Pt.0 Ch.1 of the "Rules for Classification of Ships" and the "Rules for Classification of High Speed, Light Craft and Naval Surface Craft"

    Column I Column II
    Parameters Location within main area Main Areas On Board
    Machinery spaces Control Room, Acc. Bridge Pump room, Holds, Rooms with no heating Open deck
    Temperature Inside cubicles, desks, with temp rise 5oC or more B B B D D
    All other locations A A A C D
    Humidity Locations where special precautions are taken to avoid condensation A A A A A
    All other locations B B B B B
    Vibration On Machinery such as internal combustion engines, compressors, pumps, including piping on such machinery B - - B B
    Masts - - - - C
    All other locations A A A A A
    EMC All locations within specified main areas A A B A B
    Enclosure Submerged application D - - D D
    Below floor plates in engine room C - - - -
    All other locations B A A B C
  • IEC 61850-3

    IEC 61850-3 is a standard that outlines a comprehensive safety framework for substation automation, transmission & delivery (T&D) automation, and smart grid application. The standard emphasizes the EMI immunity and environmental requirements for communications networks. The product that meets the IEC 61850-3 standard provides full-range, redundant power supply which ensures the high quality of electricity transmission.

     
    The equipment that meets the IEC 61850-3 requirement have the following characteristics:
    Reliability Substation automation system (SAS) will keep operating when single communication component breaks down.
    Availability The equipment provides system and data backup and avoids impacts from system failover.
    Maintainability Well trained technicians will provide on-line and on-site maintenance service.
    Safety The equipment could keep the system from potential risks and instability.
    Data Integrity The system will keep the false data at certain levels to meet the I1, I2, or I3 standard.
     
     
  • ISO 13485

    ISO 13485 is an International Organization for Standardization (ISO) standard, published in 2003, a quality management system standard specifically for the medical devices industry. It was written to support medical device manufacturers indesigning quality management systems that establish and maintain the effectiveness of their processes. It ensures the consistent design,development, production, installation, and delivery of medical devices that are safe for their intended purpose.

 
 

Quality Systems

Winmate developed and implemented a quality management system based on a process management approach which has demonstrateed its ability to provide consistent products that meet customer and applicable regulatory requirements, and to address customer satisfaction through the effective application of the system, including continual improvement and the prevention of non-conformity. The quality system complies with the international standard ISO 9001:2008 and the standards which apply to related industries.
 
Next: Reliability & Service
 

Questions ?

  Request More Information
  Tel : 770-274-3381
  Subscribe to Newsletter
  Get a Quote
 

TOP

 

Share

Follow us

How to buy

> Contact Winmate
> Get Support

Get the Newsletter

Our Products

> Tablet
> Handheld
> Ultra Rugged Tablets
> Fixed-Mount Computer
> Vehicle-Mount Computer

Our Industries

> Transportation
> Field Service
> Logistics
> Supply Chain
> Warehouse
> Oil & Gas